Impact of Implementing Preanalytical Laboratory Standards on the Diagnosis of Gestational Diabetes Mellitus: A Prospective Observational Study




Clinical Chemistry Podcast RSS show

Summary: Gestational diabetes mellitus (GDM) is associated with adverse pregnancy outcomes, but risk is reduced with identification and early treatment. Glucose measurements are affected by preanalytical sample handling, such as temperature of storage, phlebotomy–analysis interval, and use of a glycolysis inhibitor. We evaluated glucose concentrations and the incidence of GDM after strict implementation of the American Diabetes Association (ADA) preanalytical guidelines, compared with usual hospital conditions.